            NYKP Series

            Dual Power Automatic Transfer Switch

            NYKP2 series(16A-3200A)

            NYKP1 series(6A-630A)

            Intelligent Fast Safe Comprehensive

            PRODUCT OVERVIEW

            Dual power automatic transfer switch is a power conversion equipment, featuring fast response, strong stability and high reliability; it has the protection functions for short circuit, grounding, phase loss and over-voltage; widely used in power plants, substations, coal mines, ports, factories, airports, and other important places for the protection of circuits and equipment safety, realizing intelligent control and management.

            FAST RESPONSE AND SWITCHING

            Dual power supplies are driven by motors and solenoids for fast.

            ISOLATION FUNCTION MAKES USERS MORE ASSURED

            The front end of the product can be set with an isolation switch or with isolation function,providing obvious line disconnection points to protect personal safety during maintenance.

            TECHNICAL PARAMETERS

            NYKP2 Series

            • Rated operating voltage: 400V
            • Rated operating current: 16-3200A
            • Product category: PC grade
            • Number of poles: 2P, 3P, 4P
            • Switching mode: automatic charge and automatic recovery, automatic charge without automatic recovery
            • Power supply mode: grid - grid, grid - power generation
            • Use category: AC-33iB, AC-33B

            NYKP1 series

            • Rated operating voltage: 400V
            • Rated operating current: 6-630A
            • Product category: CB grade
            • Number of poles: 3P, 4P
            • Switching mode: automatic charge and automatic recovery, automatic charge without automatic recovery
            • Power supply mode: grid - grid, grid - power generation
            • Use category: AC-33iB
            Technical Parameters

            NYKP2-G Series DUAL Power Supply

            Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit making capacity Icm(kA)Icm(kA) Rated short-time withstand current Icw (kA) Icw(kA) Use category
            NYKP2-GA AC400 100 16、20、25、32、40、50、63、80、100 3P、4P 8 5kA/30ms AC-33B
            NYKP2-GA 250 125、160、200、225、250 10kA/60ms
            NYKP2-GA 630 315、350、400、500、630 12.6kA/60ms
            NYKP2-GA 1600 800、1000、1250、1600 32kA/60ms AC-33iB
            NYKP2-GA 3200 2000、2500、3200 50kA/1s

            NYKP2-LA/L/SA/S Series DUAL Power Supply

            Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit making and Breaking capacity Icm(kA) Operation cycles times/hour Rated short-time withstand current Icw (kA) Icw(kA) Use category
            NYKP2-SA、S、LA、L AC230V(2P), AC400V(3P、4P) 125 20、32、40、50、63、80、 100、125 2P、3P、4P 25 120 10kA/30ms AC-33B
            NYKP2-SA、S、LA、L 250 125、160、200、250 2P、3P、4P 25 10kA/30ms AC-33B
            NYKP2-SA、S、LA、L 630 250、315、400、500、630 2P、3P、4P 30 12.6kA/60ms AC-33B

            NYKP2 Series DUAL Power Controller Summary

            Controller Model NYKP2 Series
            Product model y-701 y-702
            Installation method Split type
            Display mode Indicator light display LCD display
            Rated working system Uninterrupted working system
            Automatic charge and automatic recovery
            Automatic charge without automatic recovery
            Mutual backup
            Automatic start generator function
            Common power supply detection Four-phase power loss detection, three-phase over-voltage and
            Backup power supply detection Four-phase power loss detection, three-phase over-voltage and
            Passive fire protection input
            Active fire protection input (DC9-36V)(DC9-36V)
            Adjustable transfer delay
            Real-time voltage display
            Common and backup power supply indication
            Adjustable overvoltage and undervoltage for common and backup power
            Adjustable start and stop time of generator ●(F/F1)
            Programmable output port
            RS485Electrical energy measurement

            NYKP1 Series DUAL Power Supply

            Model Rated operating voltage Ue(V) Rated impulse withstand voltage Uimp(kV) Casing current Inm(A) Rated currentIn(A) Number of poles Rated short-circuit breaking capacity Icn (kA) Rated short-circuit making capacity Icm(kA)Icm(kA) Product code Use category
            NYKP1 AC400 8 63 6、10、16、20、25、 32、40、50、63 3P、4P 5 120 M:Basic type M1: Fire extinguishing type AC-33iB

            NYKP1A Series DUAL Power Supply

            Model Rated operating voltage Ue(V) Casing current Inm(A) Rated currentIn(A) Number of poles Operating mode Transfer time Mechanical life(Times) Electrical life (times) Controller
            NYKP1A AC400 63 6、10、16、20、25、 32、40、50、63 4P R(Automatic charge and automatic recovery)
            S(Automatic charge without automatic recovery)
            F(grid-power generation)
            ≤2s 10000 4500
            NYKP1A 125 63、80、100、125 ≤3s+delay time 7000 3000 W2
            W3
            NYKP1A 250 160、180、200、225、250 5000 2000
            NYKP1A 630 315、350、400、500、630 5000 2000

            NYKP1 Series Dual Power Controller Summary

            Product model NYKP1 Series
            Controller Model W2 W3
            Installation method Split type
            Display mode Digital display LCD display
            Rated working system
            Automatic charge and automatic recovery
            Automatic charge without automatic recovery
            Mutual backup
            Automatic start generator function
            Common power supply detection
            Backup power supply detection
            Passive fire protection input
            Active fire protection input (DC9-36V)(DC9-36V)
            Adjustable transfer delay
            Real-time voltage display
            Common and backup power supply indication
            Adjustable overvoltage and undervoltage for common and backup power
            Adjustable start and stop time of generator
            Programmable output port
            RS485Electrical energy measurement
            Selection table

            NYKP2-G Series DUAL Power Supply

            NYKP2 100 GA 4P 100A RF Additional functions
            Product code Casing current Product category Pole No. Rated current Operating mode Additional functions
            NYKP2:
            Dual power automatic transfer switch
            100A
            250A
            630A
            1600A
            3200A
            GA: Electric motor type
            GA1: Electric motor type
            3P:3 pole
            4P:4 pole
            16A、20A
            25A、32A
            40A、50A
            63A、80A
            100A、125A
            160A、200A
            225A、250A
            315A、350A
            400A、500A
            630A、800A
            1250A
            1600A
            2000A
            2500A
            3200A
            R:Automatic charge and automatic recovery
            S:Automatic charge without automatic recovery
            F:Grid generation
            RF:Automatic charge and automatic recovery+Grid generation
            Y-701
            Y-702

            NYKP2-LA/L/SA/S Series DUAL Power Supply

            NYKP2 125 SA 4P 100A RF Additional functions
            Product code Casing current Product category Pole No. Rated current Operating mode Additional functions
            NYKP2:
            Dual power automatic transfer switch
            125A
            250A
            630A
            SA: Integrated three-section type
            LA: Integrated two-section type
            S:Split three-section type
            L:Split two-section type
            2P:2 pole
            3P:3 pole
            4P:4 pole
            20A、32A、 40A、
            50A、 63A、80A、
            100A、125A、 160A、
            200A、 250A、315A、
            400A、500A、630A
            R:Automatic charge and automatic recovery
            S:Automatic charge without automatic recovery
            F:Grid generation
            RF:Automatic charge and automatic recovery+Grid generation
            Y-701
            Y-702

            Note:?  GA series equipped with standard fire protection function
            ?  GA1 series does not include fire protection function
            ?  GA series with automatic charge without automatic recovery function should be equipped with Y-701/Y-702 controller
            ?   GA series with communication function should be equipped with Y-702 controller

            NYKP1 Series DUAL Power Supply

            NYKP1 63 M 3P 63A RF C type
            Product code Casing current Product category Pole No. Rated current Operating mode Tripping type
            NYKP1:
            Dual power automatic transfer switch
            63A Model M:Basic type
            M1 type:Fire protection type
            3P:3 pole
            4P:4 pole
            6A、10A、 16A、
            20A、 25A、32A、
            40A、50A、 63A
            R:Automatic charge and automatic recovery
            S:Automatic charge without automatic recovery
            F:Grid generation
            RF:Automatic charge and automatic recovery+Grid generation
            C type
            D type

            Note: KLDCB1 is a CB grade dual power supply switch, the execution unit is a miniature circuit breaker, with C characteristics by default

            NYKP1A Series DUAL Power Supply

            NYKP1A 125 4P 63A RF Additional functions
            Product code Casing current Pole No. Rated current Operating mode Additional functions
            NYKP1A:
            Dual power automatic transfer switch
            63A
            125A
            250A
            630A
            4P:4 pole 6A、10A
            16A、20A
            25A、32A
            40A、50A
            63A、80A
            100A、125A
            160A、180A
            200A、225A
            250A、315A
            350A、400A
            500A、630A
            R:Automatic charge and automatic recovery
            S:Automatic charge without automatic recovery
            F:Grid generation
            RF:Automatic charge and automatic recovery+Grid generation
            W2
            W3
            T:Electrical energy measurement

            Note: The execution unit of NYKP1A is a miniature circuit breaker, with C characteristics by default. others are molded case circuit breaker.

            Technical Parameters

            NYKP2-G Series DUAL Power Supply

            • Rated operating voltage (V):AC400

              Current shell frame Inm (A) :16、20、25、32、40、50、63、80、100

              Number of poles:3P、4P

              Rated short-circuit making capacity Icm(kA)lcm(kA):8

              Rated short-time withstand current Icw (kA) Icw(kA):5kA/30ms

              Use category:AC-33B

            • Rated operating voltage (V):AC400

              Current shell frame Inm (A) :125、160、200、225、250

              Number of poles:3P、4P

              Rated short-circuit making capacity Icm(kA)lcm(kA):8

              Rated short-time withstand current Icw (kA) Icw(kA):10kA/60ms

              Use category:AC-33B

            • Rated operating voltage (V):AC400

              Current shell frame Inm (A) :315、350、400、500、630

              Number of poles:3P、4P

              Rated short-circuit making capacity Icm(kA)lcm(kA):8

              Rated short-time withstand current Icw (kA) Icw(kA):12.6kA/60ms

              Use category:AC-33B

            • Rated operating voltage (V):AC400

              Current shell frame Inm (A) :800、1000、1250、1600

              Number of poles:3P、4P

              Rated short-circuit making capacity Icm(kA)lcm(kA):8

              Rated short-time withstand current Icw (kA) Icw(kA):32kA/60ms

              Use category:AC-33iB

            • Rated operating voltage (V):AC400

              Current shell frame Inm (A) :2000、2500、3200

              Number of poles:3P、4P

              Rated short-circuit making capacity Icm(kA)lcn(kA):8

              Rated short-time withstand current Icw (kA) Icw(kA):50kA/1s

              Use category:AC-33iB

            NYKP2-LA/L/SA/S Series DUAL Power Supply

            • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

              Current shell frame Inm (A) :20、32、40、50、63、80、100、125

              Number of poles:2P、3P、4P

              Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):25

              Operation cycles times/hour:120

              Rated short-time withstand current Icw (kA) Icw(kA):10kA/30ms

              Use category:AC-33iB

            • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

              Current shell frame Inm (A) :125、160、200、250

              Number of poles:2P、3P、4P

              Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):25

              Operation cycles times/hour:120

              Rated short-time withstand current Icw (kA) Icw(kA):10kA/30ms

              Use category:AC-33iB

            • Rated operating voltage (V):AC230V(2P),AC400V(3P、4P)

              Current shell frame Inm (A) :250、315、400、500、630

              Number of poles:2P、3P、4P

              Rated short-circuit making and breaking capacityIcm (kA) lcm(kA):30

              Operation cycles times/hour:120

              Rated short-time withstand current Icw (kA) Icw(kA):12.6kA/60ms

              Use category:AC-33iB

            NYKP2 Series Dual Power Controller Summary

            • Installation method:Split type

              Display mode:Indicator light display

              Rated working system:Uninterrupted working system

              Automatic charge and automatic recovery:have

              Automatic charge without automatic recovery:have

              Mutual backup:have

              Automatic start generator function:have

              Common power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

              Backup power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

              Passive fire protection input:have

              Active fire protection input (DC9-36V):have

              Adjustable transfer delay:have

              Real-time voltage display:not have

              Common and backup power supply indication:have

              Adjustable overvoltage and undervoltage for common and backup power:have

              Adjustable start and stop time of generator:have

              Programmable output port:not have

              RS485 communication function:not have

            • Installation method:Split type

              Display mode:LCD display

              Rated working system:Uninterrupted working system

              Automatic charge and automatic recovery:have

              Automatic charge without automatic recovery:have

              Mutual backup:have

              Automatic start generator function:have

              Common power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

              Backup power supply detection: Four-phase power loss detection, three-phase over-voltage and under-voltage detection

              Passive fire protection input:have

              Active fire protection input (DC9-36V) :have

              Adjustable transfer delay:have

              Real-time voltage display:have

              Common and backup power supply indication:have

              Adjustable overvoltage and undervoltage for common and backup power:have

              Adjustable start and stop time of generator:have(F/F1)

              Programmable output port:have

              RS485 communication function:have

            NYKP1 Series DUAL Power Supply

            • Rated operating voltage (V):AC400V

              Rated impulse withstand voltage Uimp(kV):8

              Current shell frame Inm (A) :6、10、16、20、25、32、40、50、63

              Number of poles:3P、4P

              Rated ultimate breaking capacity lcm(kA):5

              Rated short-circuit making capacity Icm(kA)lcn(kA):120

              Product code :M: Basic type M1: Fire extinguishing type

              Use category:AC-33iB

            NYKP1A Series DUAL Power Supply

            • Rated operating voltage (V):AC400V

              Rated impulse withstand voltage Uimp(kV):8

              Current shell frame Inm (A) :6、10、16、20、25、32、40、50、63

              Number of poles:4P

              Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

              Transfer time:≤2s

              Mechanical life (times) :10000

              Electrical life (times) :4500

            • Rated operating voltage (V):AC400V

              Rated impulse withstand voltage Uimp(kV):8

              Current shell frame Inm (A) :63、80、100、125

              Number of poles:4P

              Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

              Transfer time:≤3s+delay time

              Mechanical life (times) :7000

              Electrical life (times) :3000

              Controller:W2、W3

            • Rated operating voltage (V):AC400V

              Rated impulse withstand voltage Uimp(kV):8

              Current shell frame Inm (A) :160、180、200、225、250

              Number of poles:4P

              Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

              Transfer time:≤3s+delay time

              Mechanical life (times) :5000

              Electrical life (times) :2000

              Controller:W2、W3

            • Rated operating voltage (V):AC400V

              Rated impulse withstand voltage Uimp(kV):8

              Current shell frame Inm (A) :315、350、400、500、630

              Number of poles:4P

              Operating mode :R(Automatic charge and automatic recovery)、S(Automatic charge without automatic recovery)、F(grid-power generation)

              Transfer time:≤3s+delay time

              Mechanical life (times) :5000

              Electrical life (times) :2000

              Controller:W2、W3

            NYKP1 Series Dual Power Controller Summary

            • Installation method:Split type

              Display mode:Digital display

              Rated working system:not have

              Automatic charge and automatic recovery:have

              Automatic charge without automatic recovery:have

              Mutual backup:have

              Automatic start generator function:have

              Common power supply detection:have

              Backup power supply detection:have

              Passive fire protection input:have

              Active fire protection input (DC9-36V) :have

              Adjustable transfer delay:have

              Real-time voltage display:have

              Common and backup power supply indication:have

              Adjustable overvoltage and undervoltage for common and backup power:have

              Adjustable start and stop time of generator:have

              Programmable output port:have

              RS485 communication function:have

            • Installation method:Split type

              Display mode:LCD display

              Rated working system:not have

              Automatic charge and automatic recovery:have

              Automatic charge without automatic recovery:have

              Mutual backup:have

              Automatic start generator function:have

              Common power supply detection:have

              Backup power supply detection:have

              Passive fire protection input:have

              Active fire protection input (DC9-36V):have

              Adjustable transfer delay:have

              Real-time voltage display:have

              Common and backup power supply indication:have

              Adjustable overvoltage and undervoltage for common and backup power:have

              Adjustable start and stop time of generator:have

              Programmable output port:have

              RS485 communication function:have

            Selection table


            NYKP2-G Series DUAL Power Supply

            • Product code :NYKP2: Dual power automatic transfer switch

              Current shell frame :100A、250A、630A、1600A、3200A

              Product category :GA、GA1

              Pole code :3P、4P

              Rated current:16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、160A、200A、225A、250A、315A、350A、400A、500A、630A、800A、1250A、1600A、2000A、2500A、3200A

              Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

              Additional features:Y-701、Y-702

            NYKP2-LA/L/SA/S Series DUAL Power Supply

            • Product code :NYKP2: Dual power automatic transfer switch

              Current shell frame :125A、250A、630A

              Product category:SA:Integrated three-section type、LA: Integrated two-section type 、S: Split three-section type、L:Split two-section type

              Pole code :2P、3P、4P

              Rated current: 20A、32A、40A、50A、63A、80A、100A、125A、160A、200A、250A、315A、400A、500A、630A

              Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

              Additional features:Y-701、Y-702

            Note: GA series equipped with standard fire protection function
            GA1 series does not include fire protection function
            GA series with automatic charge without automatic recovery function should be equipped with Y-701/Y-702 controller
            GA series with communication function should be equipped with Y-702 controller

            NYKP1 Series DUAL Power Supply

            • Product code :NYKP1: Dual power automatic transfer switch

              Current shell frame :63A

              Product category:Type M: Basic type、Type M1: Fire protection type

              Pole code :3P、4P

              Rated current:6A、10A、16A、20A、32A、40A、50A、63A

              Operating mode :R:Automatic charge and automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

              Tripping type:Type C 、Type D

            Note: KLDCB1 is a CB grade dual power supply switch, the execution unit is a miniature circuit breaker, with C characteristics by default

            NYKP1A Series DUAL Power Supply

            • Product code :NYKP1A: Dual power automatic transfer switch

              Current shell frame :63A、125A、250A、630A

              Pole code :4P

              Rated current:6A、10A、16A、20A、32A、40A、50A、63A、80A、100A、125A、160A、180A、200A、225A、250A、315A、350A、400A、500A、630A

              Operating mode :R:Automatic charge and automatic recovery、S:Automatic charge without automatic recovery、F:Grid generation、RF:Automatic charge and automatic recovery+Grid generation

              Additional features:W2、W3、T: Communication function

            Note: The execution unit of NYKP1A is a miniature circuit breaker, with C characteristics by default. others are molded case circuit breaker.